Customization: | Available |
---|---|
Function: | Water Boiler, Hot Water Boiler |
Fuel: | Gas-Fired |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
*Power model: 60kW, 80kW, 99kW, 120kW *Variable frequency regulation:15%~100% step-less frequency conversion adjustment *High efficiency and energy saving: efficiency up to 108%; *Low nitrogen environmental protection: NOx emission as low as 30mg/m³ (standard working condition); *Material: cast silicon aluminum host heat exchanger, high efficiency, strong corrosion-resistance; *Space advantage: compact structure; Small volume; Lightweight; Easy to install *Stable operation: the use of advanced imported accessories to ensure safe and reliable operation; *Intelligent comfort: unattended, accurate temperature control, make heating more comfortable; *Long service life: the core components such as the Cast silicon aluminum are designed to last more than 20 years |
Technical Data | Unit | Produce Model&Specification | |||
GARC-LB60 | GARC-LB80 | GARC-LB99 | GARC-LB120 | ||
Rated heat output | kW | 60 | 80 | 99 | 120 |
Max. air consumption at rated thermal power | m³/h | 6 | 8 | 9.9 | 12 |
Hot water supply capabiliy(△t=20°ºC) | m³/h | 2.6 | 3.5 | 4.3 | 5.2 |
Maximum water flow | m³/h | 5.2 | 7 | 8.6 | 10.4 |
Mini.Max. water system pressure | bar | 0.2/3 | 0.2/3 | 0.2/3 | 0.2/3 |
Max. outlet water temperature | ºC | 90 | 90 | 90 | 90 |
Thermal efficiency at max. load 80°C~60°C | % | 96 | 96 | 96 | 96 |
Thermal efficiency at max. load 50°C~30°C | % | 103 | 103 | 103 | 103 |
Thermal efficiency at 30% load (outlet water temperature 30°C) | % | 108 | 108 | 108 | 108 |
CO emissions | ppm | <40 | <40 | <40 | <40 |
NOx emissions | mg/m | <30 | <30 | <30 | <30 |
ype of gas supply | 12T | 12T | 12T | 12T | |
Gas pressure(dynamic pressure) | kPa | 3~5 | 3~5 | 3~5 | 3~5 |
Size of gas interface | DN25 | DN25 | DN25 | DN25 | |
Size of outlet water interface | DN32 | DN32 | DN32 | DN32 | |
Size of return water interface | DN32 | DN32 | DN32 | DN32 | |
Size of condensate outlet interface | DN15 | DN15 | DN15 | DN15 | |
Diameter of smoke outlet | mm | 110 | 110 | 110 | 110 |
Length of the gas-fired floor-standing boiler | mm | 720 | 720 | 720 | 720 |
Width of the gas-fired floor-standing boiler | mm | 700 | 700 | 700 | 700 |
Height of the gas-fired floor-standing boiler | mm | 1220 | 1220 | 1220 | 1220 |
Net weight of the boiler | kg | 165 | 185 | 185 | 185 |
Power source required | V/Hz | 230/50 | 230/50 | 230/50 | 230/50 |
Noise | dB | <50 | <50 | <50 | <50 |
Electric power consumption | W | 300 | 300 | 300 | 300 |
Reference heating area | m2 | 700 | 900 | 1100 | 1300 |
High Effiiciency | Energy-Saving | Evironmental Protection | Safty | Reliable | Low Exhaust Temperature | Intelligent |
Long Service Life | Wide Temperature Range | Silent Operation | Wide Adaptability | Personlized Design | Small Occupation Area | Worry-free Use |
Performance Comparison | Convential Gas-Fired Boiler | Fully Premixed Low Nitrogen Condensing Gas-Fired Boiler |
Thermal Efficiency | 90% | 108% |
NOx Emission | 2 levels, basic level | 5 levels, the cleanest level |
Heating-Load Turndown Tation | gear/step adjustment | 15%~100 stepless adjustment on demand |
Average Gas Consumption per Square Meter in a Heating Season(4months, in North China) | 8-10m3 | 5-6m3 |
Combustion Noise During Heating Operation | using ordinary blowers, high noise and high power consumption | using the world's top stepless frequency convertion blowers/fans, the noise is extremly low |
Construction and Installation | complicated installation and large space required | simple installation, requires little space |
Boiler Size(1MW Boiler) | 12m3 | 3m3 |
Boiler Weight | large mas,heavy weight, inconventient installation, need lifting equipment, high requirements for load-bearing mechanisms, and poor safty | the weight of cast aluminum silicon magnesium alloy is only 1/10 of that of carbon steel. Casters can be positioned and installed, very easy to transport and move |
Gas outage protection | System water shortage protection | Gas pressure protection | Air pressure startup detection |
Gas flow air pulse compensation | Post-purge protection | Pre-purge protection | Flue gas temperature protection |
Freeze protection | Ion flameout protection | Water temperature sensor failure protection | System water overpressure protection |
Condensate seal blockage protection | Anitioxidant corrosion protection | Over temperature protection | Ultra wide votage operation |